The 2025 revision of ICC 700 reshapes how green certification interacts with energy code, durability, and indoor air quality.
NAHB Research Center released the ICC 700-2025 National Green Building Standard in late 2024, and the deltas from the 2023 edition are concentrated in the categories that drive certification scoring for mid-rise multifamily: energy efficiency, indoor air quality, and building durability. Builders who locked their specifications around NGBS-2023 paths are finding that several previously accepted practices no longer carry the same points, and a few prescriptive paths have been tightened to align with ASHRAE 90.1-2022 baselines.
The issue is not that NGBS 2023 was wrong — it was simply calibrated to a different reference point. With the 2024 IECC now adopted in growing portions of the Midwest, and with ENERGY STAR Multifamily New Construction v3.2 establishing a stricter thermal envelope baseline, NGBS 2025 had to move in step. Projects that pursue NGBS Green Certified under the 2025 standard without verifying air leakage, duct leakage, and HVAC performance against the new performance paths will lose certification points they expected to bank.
The most common error HECS finds on multifamily projects is treating air sealing and duct leakage as a single trade activity. They are separate verification events under NGBS 2025, with distinct thresholds, and conflating them during pre-drywall inspection is the fastest way to fail a verifier walkthrough.
Need HECS for your project?
NCI-certified testing and certification across KY, IN, OH, TN, IL, MO.
Call (859) 983-7382 Get a QuoteICC 700-2025 retains the four-tier certification structure — Bronze, Silver, Gold, and Emerald — but rebases the energy efficiency chapter against ASHRAE 90.1-2022 rather than the 2016 reference used in NGBS-2023. The practical effect is that builders running performance paths under ENERGY STAR MFNC v3.2 or the 2024 IECC are now closer to NGBS Gold compliance than they were two years ago, but the verification documentation is more demanding.
Key changes worth flagging:
The EPA radon map remains the reference for radon-resistant construction requirements under Chapter 9. Kentucky and Indiana sit in Zone 1 or Zone 2 depending on county, and HECS verifies passive radon systems where required by local jurisdiction overlay.
HECS recommends that multifamily builders schedule NGBS verification as a three-event process rather than a single end-of-project inspection. The first event should occur at pre-drywall, when the building envelope and duct system are accessible. The second event covers insulation and air barrier continuity after drywall. The third is the final performance verification, including blower door testing, duct leakage testing, and HVAC functional testing.
This staged approach matters because NGBS 2025 verification requires a verifier signature at each milestone — the verifier cannot retroactively confirm work that was concealed before inspection. HECS has seen projects lose Emerald certification because a pre-drywall photo log was missing a single zone damper, or because duct leakage results were not transmitted to the verifier before drywall closed the chase.
The third-party verifier role is distinct from the rater or energy modeler. Under NGBS Green Certified Verifier protocols, the verifier confirms that design documents, material certifications, and field performance data together satisfy the standard. HECS provides this verification function with an NCI Certified air balancer on staff, which means the same technician who performs the blower door and duct leakage tests can also document the HVAC balance results in the format the NGBS reviewer expects.
The HECS verification package for an NGBS 2025 multifamily project includes:
| Verification Event | Standard Reference | HECS Deliverable |
|---|---|---|
| Pre-drywall | NGBS 2025 Ch. 7, 11 | Photo-logged inspection report |
| Final performance | RESNET, ASHRAE 111 | Blower door, duct leakage, balance report |
| IAQ documentation | ASHRAE 62.2-2022 | Ventilation rate worksheet |
| Radon | EPA Map, NGBS 2025 Ch. 9 | System verification checklist |
The performance path under NGBS 2025 lets builders trade prescriptive measures against an energy model, but the documentation must show that the as-built performance matches the modeled performance. HECS has reviewed projects where the energy model showed a 7% margin against the target, but actual blower door and duct leakage results pushed as-built performance below the modeled number. The certification reviewer flags this as a documentation failure, not a design failure — but the effect is the same: points are not awarded.
The mitigation is straightforward. Test before drywall closes. Run a preliminary blower door at pre-drywall to confirm envelope airtightness is on track. If numbers are high, seal and retest. By the time drywall is up, remediation costs roughly five to eight times what pre-drywall sealing would have cost.
Does NGBS 2025 require duct leakage testing for every multifamily unit? Yes. Chapter 7 now requires tested duct leakage per RESNET standards for in-unit HVAC systems, not just a visual inspection at rough-in. Builders can sample per the standard's testing protocol, but every sampled unit must meet the leakage-to-outside threshold.
Can a project pursue both NGBS 2025 Green Certification and FORTIFIED Home 2025? Yes, and there is overlap in the durability chapters that can reduce duplicate documentation. HECS coordinates the verifier functions so a single set of field photos can satisfy both programs where the standards align.
How does NGBS 2025 interact with ENERGY STAR MFNC v3.2? ENERGY STAR MFNC v3.2 remains an acceptable compliance path for NGBS Chapter 7 energy points, but the verifier must document the ENERGY STAR certificate and the supporting test results separately. HECS pulls both into a single verification packet.
HECS provides NGBS Green Certified Verifier services across Kentucky, Indiana, Ohio, Tennessee, Illinois, and Missouri, with on-site scheduling typically within two to three weeks of contract. The relevant HECS services for multifamily NGBS 2025 projects include blower door testing, duct leakage testing, HVAC testing and balancing, and radon testing. To scope a project, call (859) 983-7382 or email [email protected]. Project intake and scheduling are handled through hecsusa.com/contact/, and the full service catalog is available at hecsusa.com/services/.
One short email per month with code updates, testing data, and what HECS is seeing in the field across KY / IN / OH / TN / IL / MO. Unsubscribe in one click.